|  |
 |
| Item number: CIEN7-38221197 Manufacturer no.: 699CA000017 EAN/GTIN: 8436035921836 |
| |
|
|  |  |
 | Salicru's SLC TWIN PRO2 series is a UPS range in a tower format equipped with on-line double-conversion technology and the latest features to make it an advanced protection system for sensitive and critical loads. High output power factor (PF=0.9) to ensure availability to all types of loads. Full control through status information via LCD display and keypad. And extensive monitoring and communication options via the built-in USB HID interface, an intelligent slot for SNMP cards or relays and a wide range of software packages available – free monitoring version downloadable for Windows, Linux, Unix or Mac and packages available for multi servers or virtualised systems. For facilities that require more back-up time, there is a possibility of backup extensions using UPSs with extra charger and additional battery modules. Also notable is the possibility of Eco-mode operation to improve the efficiency of the device, EPO (emergency power off) functions, operation as a frequency converter and built-in battery test. Salicru's SLC TWIN PRO2 range is available in power ratings of 700, 1000, 1500, 2000 and 3000 VA. More information: Weight & dimensions | Width | 190 mm |  | Depth | 399 mm |  | Height | 327 mm |  | Weight | 18400 g | Battery | Battery technology | Lead-Calcium (Pb-Ca) |  | Battery recharge time | 4 h |  | Automatic battery test | Yes |  | Off-mode charging | Yes | Operational conditions | Operating temperature (T-T) | 0 - 40 °C |  | Operating relative humidity (H-H) | 0 - 95 % |  | Operating altitude | 0 - 5000 m | Logistics data | Harmonized System (HS) code | 85078000 | Design | Form factor | Tower |  | Product colour | Black |  | Cooling type | Active |  | Built-in fan | Yes |  | Display type | LCD |  | LED indicators | Battery replacement |  | Safety | EN 62040-1:2008+A1:2013 | Features | UPS topology | Double-conversion (Online) |  | Output power capacity | 2 kVA |  | Output power | 1800 W |  | Waveform | Pure sine |  | Input operation voltage (min) | 220 V |  | Input operation voltage (max) | 240 V |  | Input frequency | 50/60 Hz |  | Output operation voltage (min) | 220 V |  | Output operation voltage (max) | 240 V |  | Output frequency regulation | 0.05 Hz |  | Output voltage regulation | 1 % |  | Number of input phases | 1 |  | Number of output phases | 1 |  | Efficiency (On-line mode) | 92 % |  | Efficiency (ECO mode) | 98 % |  | Input power factor | 0.99 |  | Output power factor | 0.9 |  | ECO mode | Yes |  | Emergency Power Off (EPO) | Yes |  | Overload capacity (1 minute) | 130 % |  | Output voltage Total Harmonic Distortion (THD) | 2 % |  | Input current Total Harmonic Distortion (THD) | 2 % |  | Noise level | 49 dB |  | Surge protection | Yes |  | Power protection features | Over current, Short circuit, Under current, Under voltage |  | Audible alarm(s) | Yes |  | Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm, Battery replacement | Ports & interfaces | AC outlet types | C13 coupler, IEC Jumpers |  | Power plug | C19 coupler |  | AC outlets quantity | 4 AC outlet(s) |  | Number of output IEC jumpers | 4 |  | USB port | Yes |  | USB 2.0 ports quantity | 1 |  | Emergency Power Off (EPO) connector | Yes | Other features | Battery type | AGM |
|
|  |  |
 | |  |  |
 | Other search terms: Voltage monitoring relay, Voltage monitoring relays, UPS, USV, UPS system, Uninterruptible power supply, UPSs, uninterruptible power supply, uninterruptible power supplies, uninterruptible power source, uninterruptible power sources |
|  |  |
| |