Intel Atom Processor C3000 Series Storage Done Right GIGABYTE and Intel bring value to the fore with this new entry level platform offering flexible storage options and requiring low power - reducing OPEX and CAPEX. Designed to support up to 16 SSDs or an 8 SSD and add-on card combination, this board offers great NAND* for your buck! (*or Optane) GIGABYTE’s precision design and engineering expertise, in combination with the Intel Atom series, enables these boards to meet the needs of SOHO and thin-edge applications, especially for media and general data storage.
Generation on Generation Improvement Intel’s new generation Atom platform is a single-chip SoC that offers extensive high-speed HSIO options and up to 16 cores at low power. With some of the highest power density (performance/watt) of Intel’s Enterprise line up, this platform is ideal for lightweight, storage-heavy applications.
Extensive I/O FFlexible I/O Adapter PCIe/SATA/USB support Performance/Watt Leadership SoC TDP of 31W Networking 2 x 10GbE Intel Ethernet Up to 20Gbs full duplex encryption with Intel QAT
Performance Efficiency Leadership This board packs a punch in performance for its size, value (CAPEX and OPEX) and power usage.
High Performance:Power Efficiency On A Compact Board 16 cores on single CPU TDP of 31W Supporting: Up to 256GB DDR4 (64GB per DIMM) 2 x 10GbE Intel Ethernet Up to 20Gbs full duplex encryption with Intel QAT 32GB eMMC to store the OS and free up SATA ports
High I/O Integration Delivers comprehensive storage options on a compact board – the highest SATA support available in the market on this platform.
High Speed I/O Switch Allows automatic switching between I/O ports Options: 16 x SATA III (from 4 mini SAS connectors) 8 x SATA III (enable 2 mini SAS connectors) and a PCIe (Gen.3 x8) Dual USB 2.0 support
TPM 2.0 Module* GIGABYTE’s Denverton platform is designed to support Trusted Platform Modules (TPM - discrete cryptographic on-board processors).
Carefully Selected Components GIGABYTE’s passive components are meticulously selected to guarantee a super stable operating environment and allow the processors and the memory to deliver their maximum performance.With some of the longest service lifetimes in the industry, our server motherboards are built with ultra long lasting components to attain the highest reliability levels.
GIGABYTE Server Management (GSM) is GIGABYTE’s proprietary multiple server remote management software platform, available as a free download from each GIGABYTE server product page. GSM is compatible with either IPMI or Redfish (RESTful API) connection interfaces, and comprises the following sub-programs:
GSM Server, a software program with an easy to use browser-based GUI to enable global remote monitoring and management of multiple GIGABYTE servers via each server node’s BMC. GSM CLI, a command-line interface program to enable global remote monitoring and management of multiple GIGABYTE servers via each server node’s BMC. GSM Agent*, a software program installed locally on each GIGABYTE server node that retrieves additional node information (CPU/Mem/HDD/PCI/…) from the OS and passes it to the BMC. This information can then be utilized by GSM Server or GSM CLI. *GSM Agent is currently compatible with Avocent MergePoint IPMI 2.0 BMC firmware, but not yet compatible with Megarac SP-X BMC firmware. GSM Mobile, a remote server management mobile APP, available for both Android and iOS. GSM Plugin, a plugin that allows the user to manage and monitor GIGABYTE server nodes within VMware’s vCenter.
Intuitive & Informative User Interface Starting from the GSM Server dashboard, the user can clearly understand the status of each node in the IT environment, including:
Node connection status (system is online/offline) Node hardware sensor status (to detect hardware anomalies). Sensors measure voltage, fan speed and temperature Node usage rate status (allowing you to timely allocate more resources when they are needed), including: Power consumption Disk/RAID usage information Memory usage rate CPU usage rate Network card / PCI information
The user can also perform various management functions, including:
Node remote access Power on / off / reset Launch iKVM Reboot BMC / BMC Account Configuration Network Configuration IPv4/IPv6 setting Alert Management SNMP trap setting Platform events filters Forwarding alerts by email BMC / BIOS / CPLD Update Power Consumption Limit Setting Group Management Create groups of nodes for BMC / BIOS update or manage power consumption settings
GSM Mobile for iOS and Android A GSM Mobile app is available for download for both iOS and Android mobile phones for remote server management on the go.
Management through VMware vCenter A GSM Plugin is available for VMware’s vCenter, allowing the user to perform remote monitoring and management of GIGABYTE server nodes without having to switch to a separate software platform.
GIGABYTE BMC Interface Easy BIOS Upgrade GIGABYTE has developed this integrated function (requiring no additional software) that allows users to update the BIOS of motherboards through the BMC controller:
No need to install core components such as CPUs, memory, drives and OS No need to power on the system (NB. PSU must be connected) Update individual (IPMI 2.0) or multiple boards simultaneously (Command Line)
Dynamic Fan Speed Control GIGABYTE servers are enabled with dynamic fan speed adjustment. Individual fan speed will be automatically adjusted according to the system’s current temperature (according to CPU, DIMM, M.2, HDD, GPU temperature sensors), to achieve the best cooling and power efficiency. When the BMC detects a temperature change, fan speed will be automatically adjusted accordingly. Fan speed profiles may also be manually created and edited* when necessary according to the user’s custom requirements.
Environmental Compliance GIGABYTE maintains its commitment to green products, and adheres to the latest RoHS regulations (in effect July 2017).
VMware Technology Alliance Partner Being a member of VMware's Technology Alliance Partner (TAP) program enables GIGABYTE to rapidly develop and certify joint solutions or go-to-market products that leverage VMware virtualization and cloud solutions, enabling our customers to modernize their data centers and implement IT infrastructure and application services with speed, agility, and cost optimization.
Enquire with your GIGABYTE sales representative for more information about combining or integrating this server product with VMware solutions. More information: Processor | Processor manufacturer | Intel | | Compatible processor series | Intel Atom® | Graphics | On-board graphics card model | Aspeed AST2400 | Technical details | Sustainability certificates | RoHS | Packaging content | Cables included | Serial | Features | Component for | Server | | Motherboard form factor | Mini-ITX | BIOS | Clear CMOS button | Yes | Network | Ethernet LAN | Yes | | Ethernet interface type | 10 Gigabit Ethernet, Gigabit Ethernet | Operational conditions | Storage temperature (T-T) | -40 - 60 °C | | Operating temperature (T-T) | 10 - 40 °C | | Operating relative humidity (H-H) | 8 - 80 % | | Storage relative humidity (H-H) | 20 - 95 % | Other features | PCI Express x8 (Gen 3.x) slots | 1 | | Quick installation guide | Yes | | Number of DIMM slots | 4 | | Number of processors supported | 1 | Storage controllers | Supported storage drive interfaces | Serial Attached SCSI (SAS) | Memory | Supported memory types | DDR4-SDRAM | | Maximum internal memory | 64 GB | | Supported memory clock speeds | 1866,2133,2400 MHz | Internal I/O | ATX Power connector (24-pin) | Yes | | CPU fan connector | Yes | | EPS power connector (8-pin) | Yes | | TPM connector | Yes | | Serial port headers | 1 | | Integrated SAS ports | 1 | Logistics data | Harmonized System (HS) code | 84733020 | Rear panel I/O ports | USB 2.0 ports quantity | 2 | | Ethernet LAN (RJ-45) ports | 2 | | VGA (D-Sub) ports quantity | 1 |
|