| Item number: 2794E-6239917 Manufacturer no.: FLUKE-718 300G EAN/GTIN: n/a |
| |
|
|  |  |
 | CSA C22.2 no. 1010.1: 1992, IEC 61010, CAT I 30V. Fluke 718, holster, TL75 test leads, AC72 crocodile clips, two 9 V batteries, instruction manual. Fluke 718 Pressure Calibrators. The Fluke 718 Pressure Calibrator provides a total pressure calibration solution for transmitters, gauges, and switches. This compact pressure calibration solution is about a third of the size of comparable instruments and weighs just one kilogram (two pounds). The unique easy to clean pump helps protect the pump from damage and provides the ability to service the pump without disassembly, even in the field. Fluke 718 series include: 718 1G – ; 623-9901 623-9901 718 30G – ; 334-9011 334-9011 718 300G – ; 623-9917 623-9917. Features and Benefits. Pressure Source and Milliamp Measurement to calibrate and maintain almost any pressure device Integrated pump is easily cleaned when accidently exposed to fluids that reduces cost of ownership and repairs and enables servicing the pump in the field Error % calculation for quicker pass/fail decision making in the field Best in class mA accuracy of 0.015% for better measurement confidence and workload coverage Min/Max/Hold to capture changing measurements Switch test feature for quicker and more accurate pressure switch testing 1G:- Range: -1 to 1psi, -68.9 mbar to 68.9 mbar, -6.89 to 6.89 kPa) 30G:- Range: -12 psi to 30 psi, (-850 mbar to 2 bar, -85 to 206.84 kPa) 300G:- Range -12 psi to 300 psi, (-850 mbar to 20 bar, -85 to 2068.42 kPa) For measuring overpressure and vacuum with an internal sensor Suitable for non-corrosive gases Pressure / vacuum hand pump with fine adjustment and relief valve (helps to protect the pump) Select from numerous technical units for the pressure Simultaneous measurement of pressure and current for simple P/I or I/P testing 24 V loop supply Zero and damp functions Test functions for push button switch: set, reset, dead zone New 1 and 300 PSI pressure ranges mean fewer extra tools required Rugged can withstand 1 m drop test 9 V battery, Dimensions 216 x 94 x 66 mm Weight 992 g LCD display More information:  |  | Maximum Pressure Measurement: | 20bar | Minimum Pressure Measurement: | -850mbar | Resolution: | 1 mbar | Data Logging: | No | Model Number (p): | 718 | Current Loop Measurement: | Yes | Maximum Operating Temperature: | +55°C | Minimum Operating Temperature: | -10°C | Weight: | 992g | Dimensions: | 216 x 94 x 66mm | Height: | 66mm | Length: | 216mm | Width: | 94mm |
|
|  |  |
 | |  |  |
 | Other search terms: Intrinsically safe loop calibrator, Intrinsically safe loop calibrators, Current calibrator, Current calibrators, Current loop calibrator, Current loop calibrators, Voltage loop calibrator, Voltage loop calibrators, 6239917, Test & Measurement, Pressure Test & Measurement, Pressure Calibrators, Fluke, FLUKE718300G |
|  |  |
| |