After the fieldbus node is assembled with the correct buscoupler and I/O modules, the end module is snapped onto the assembly. It completes the internal data circuit and ensures correct data flow.
Distance Module The separation module visually divides a fieldbus node into sections. Separation module 750-621 has power jumper contacts that can supply the power to adjacent bus modules.
Distance Module The separation module visually divides a fieldbus node into sections. Separation module 750-616 has no power jumper contacts. Operation of the adjacent I/O modules requires a supply...
The supply module provides the I/O modules with the corresponding supply potential. The maximum current at the supply module is 10A. When configuring the system, it must be ensured that this total ...
The supply module provides the I/O modules with the corresponding supply potential. The maximum current at the supply module is 10A. When configuring the system, it must be ensured that this total ...
The field side connection module provides 0 V potential for the outputs of the 8-channel output module 750-530. This eliminates the need for additional terminal blocks. The 24V supply and 0V potent...
The field side connection module provides 24V power for the inputs of the 8-channel input module 750-430/431. - This eliminates the need for additional terminal blocks. - The 24V supply and 0V pote...
The supply module provides the I/O modules with the corresponding supply potential. The maximum current at the supply module is 6.3A. When configuring the system, it must be ensured that this total...
The supply module provides the I/O modules with the corresponding supply potential. The maximum current at the supply module is 6.3A. When configuring the system, it must be ensured that this total...
The supply module provides the I/O modules with the corresponding supply potential. The maximum current at the supply module is 10A. When configuring the system, it must be ensured that this total ...
Moxa offers a complete selection of module combinations such as digital input/output modules, analog input/output modules, temperature modules, remote I/O modules, and power modules. Simply choose ...
Moxa offers a complete selection of module combinations such as digital input/output modules, analog input/output modules, temperature modules, remote I/O modules, and power modules. Simply choose ...
Moxa offers a complete selection of module combinations such as digital input/output modules, analog input/output modules, temperature modules, remote I/O modules, and power modules. Simply choose ...
This digital output module transmits control signals from the automation device to the connected actuators. All outputs are short-circuit-protected. Field and system levels are electrically isolated.
This digital input module receives control signals from digital field devices (e.g., sensors). Each input module has a noise-rejection filter. This filter is available with different time constants...
This digital input module receives control signals from digital field devices (e.g., sensors). The module is a 4-input channel, 2-conductor device. Due to its four 24V connections, four sensors may...
The supply module provides the I/O modules with the corresponding supply potential. The maximum current at the supply module is 6.3A. When configuring the system, it must be ensured that this total...
This digital input module receives control signals from digital field devices (e.g., sensors). The module is a 4-input channel, 2-conductor device. Due to its four 24V connections, four sensors may...
This digital output module transmits control signals from the automation device to the connected actuators. The module is a 4-output channel, 2-conductor device. Due to its four 0V connections, fou...
The supply module provides the I/O modules with the corresponding supply potential. The maximum current at the supply module is 6.3A. When configuring the system, it must be ensured that this total...
This digital output module transmits control signals from the automation device to the connected actuators. All outputs are short-circuit-protected. Field and system levels are electrically isolated.
This digital input module receives control signals from digital field devices (e.g., sensors). - Each input has a bridge rectifier and capacitor and current limitation for AC/DC operation. - Each i...
This digital output module transmits control signals from the automation device to the connected actuators. All outputs are short-circuit-protected. Field and system levels are electrically isolated.
This digital output module transmits control signals from the automation device to the connected actuators. All outputs are short-circuit-protected. This output module detects the following errors:...
Smallest embedded device server available—only 29 x 17 x 12.6 mm - EZPower for 3.3 to 5 VDC system power input supported - Extremely low power consumption - Uses the MiiNe, Moxa’s second generation...
Smallest embedded device server available—only 29 x 17 x 12.6 mm - EZPower for 3.3 to 5 VDC system power input supported - Extremely low power consumption - Uses the MiiNe, Moxa’s second generation...
Binary Spacer Module Binary spacer modules reserve bit addresses in the process image of a fieldbus node. The operating mode as well as the bit width can be adjusted by DIP switches on the side of ...
The supply module provides the I/O modules with the corresponding supply potential. The maximum current at the supply module is 6.3A. When configuring the system, it must be ensured that this total...
IEEE 802.3af compliant PoE pass-through - Use Moxa’s high quality and reliable second generation MiiNe SoC - Versatile choice of operation modes fulfill specific application requirements - Green de...
Bus Extension End Module The end module for the internal data bus extension 750-627 is attached to the end of the I/O terminal block like the standard end module 750-600. The block is terminated wi...
This digital output module transmits control signals from the automation device to the connected actuators. The internal system voltage triggers the relay. The NO contacts are electrically isolated...
This digital output module transmits control signals from the automation device to the connected actuators. - The internal system voltage triggers the relay. - Note that the power jumper contacts s...