Please note that the starter is not supplied with an overload. This series accepts the TF42 overload range, for example stock number ; 711-6613 711-6613. 1TVC DOL C/W Starter in Steel Enclosure IP5...
Power Rating = 5.5 kW Motor Starter Type = DOL Voltage Rating = 400 V ac Phase = 3 IP Rating = IP65 Motor Starter Functionality = Automatic Overall Length = 230mm Enclosure = Yes Overall Width = 10...
Please note that the starter is not supplied with an overload. This series accepts the TF42 overload range, for example stock number ; 711-6613 711-6613. 1TVC DOL C/W Starter in Steel Enclosure IP5...
Power Rating = 2.2 kW Range = MMS116, MMS132 Voltage Rating = 690 V ac Phase = 3 Current Rating = 6.3 A Number of Poles = 3 Motor Starter Functionality = Manual
Power Rating = 4 kW Range = MMS116, MMS132 Voltage Rating = 690 V ac Phase = 3 Current Rating = 10 A Number of Poles = 3 Motor Starter Functionality = Manual
The MS116-20 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 20.0 A. This de...
Power Rating = 7.5 kW Motor Starter Type = Manual Voltage Rating = 690 V ac Phase = 3 Current Rating = 16 A Number of Poles = 3 Motor Starter Functionality = Manual
PSR - Compact Range Softstarter. The PSR range is the most compact of all ABB ‘s softstarter ranges. The compact PSR range makes it possible to fit many devices into the same enclosure. The setup o...
The softstarter PSR3-600-70 has a rated maximum operational current of 3 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR f...
The softstarter PSR30-600-11 has a rated maximum operational current of 30 A with an operating voltage span from 208...600 V AC. The rated control voltage is 24 V AC/DC. PSR features a two-phase co...
The softstarter PSR30-600-70 has a rated maximum operational current of 30 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR...
The softstarter PSR37-600-70 has a rated maximum operational current of 37 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR...
The softstarter PSR6-600-70 has a rated maximum operational current of 6 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR f...
The softstarter PSR9-600-70 has a rated maximum operational current of 9 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR f...
The softstarter PSR85-600-70 has a rated maximum operational current of 85 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR...
The softstarter PSR12-600-70 has a rated maximum operational current of 12 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR...
Power Rating = 11 kW Motor Starter Type = Star Delta Voltage Rating = 400 V ac Current Rating = 22 A Number of Poles = 3P Overall Length = 68mm Overall Width = 158mm Overall Depth = 117mm
EATON Open Chassis Star Delta Starters. Eaton's range of open chassis Star Delta starters are designed for use within customised enclosures, enabling quick and easy installation and direct mounting...
EATON Open Chassis Star Delta Starters. Eaton's range of open chassis Star Delta starters are designed for use within customised enclosures, enabling quick and easy installation and direct mounting...
Power Rating = 0.75 kW Motor Starter Type = DOL Voltage Rating = 400 V ac Phase = 1 IP Rating = IP65 Number of Poles = SP + N Motor Starter Functionality = Automatic Overall Length = 180mm Enclosur...
FLC figures quoted are maximum, other overload ratings can be used dependent on FLC rating. D.O.L - Steel Enclosure. IP55 sheet steel enclosed starter complete with isolator for DOL applications to...
FLC figures quoted are maximum, other overload ratings can be used dependent on FLC rating. D.O.L - Steel Enclosure. IP55 sheet steel enclosed starter complete with isolator for DOL applications to...
IEC/EN 60529, DIN 43660, EN 50262. FLC figures quoted are maximum, other overload ratings can be used dependant on FLC rating. EATON XDP DOL Starter Series with Isolator. Providing reliability and ...
EATON Open Chassis Star Delta Starters. Eaton's range of open chassis Star Delta starters are designed for use within customised enclosures, enabling quick and easy installation and direct mounting...
Power Rating = 4 kW Motor Starter Type = DOL Voltage Rating = 230 V ac Phase = 3 IP Rating = IP65 Number of Poles = 3P + N Motor Starter Functionality = Automatic Overall Length = 180mm Enclosure =...
FLC figures quoted are maximum, other overload ratings can be used dependent on FLC rating. D.O.L - Steel Enclosure. IP55 sheet steel enclosed starter complete with isolator for DOL applications to...
FLC figures quoted are maximum, other overload ratings can be used dependent on FLC rating. The starters which use the X Start range of components are not compatible with DILM components. Reversing...
IEC/EN 60529, DIN 43660, EN 50262. FLC figures quoted are maximum, other overload ratings can be used dependant on FLC rating. EATON XDP DOL Starter Series with Isolator. Providing reliability and ...
FLC figures quoted are maximum, other overload ratings can be used dependant on FLC rating.The starters which use the X Start range of components are not compatible with DILM components. Reversing ...