Device Type = Surge Arrestor Maximum Surge Current = 20kA Range = SMISSLINE TP Impulse Discharge Current = 20kA Length = 90mm Width = 72mm Depth = 109mm Dimensions = 90 x 72 x 109mm
Not assembled screw jumpers bar, - Allows connection between consecutive blocks, - Perforated jumper bar without captive screw and washer, - The perforated jumper bar must be fitted under the washe...
ABB Surge Suppressor UnitThe ABB OVR series surge suppressor unit is a protective device to ensure that electrical equipment is not damaged by a sudden voltage spike. It has an electrical rating of...
2 stud terminals M5 x 19.5 mm 0.768 in, Equipment: H 130 self locking nut + TREP 3L washer + washer, 18 mm 0.709 in spacing adding SCH6 or INH3, Two jumpering options: 14 mm 0.551 in spacing with B...
The Phoenix Contact surge protection consisting of protective plug and base element with integrated status indicator.Efficient use of space: the narrowest pluggable surge protection solution for 4-...
The Phoenix Contact surge protection consisting of protective plug and base element with integrated status indicator.Efficient use of space: the narrowest pluggable surge protection solution for 4-...
The Phoenix Contact surge protection plug with integrated status indicator on the module for a 4-wire floating signal circuit with a high nominal current.Efficient use of space: the narrowest plugg...
The Phoenix Contact type 2 surge arrester has no mismatching of plugs, thanks to mechanical coding. It is free of leakage current to ground.Space-saving installation Easy replacement during servicing
The Phoenix Contact type 2 surge arrester has no mismatching of plugs, thanks to mechanical coding. It is free of leakage current to ground.Space-saving installation Easy replacement during servicing
The Phoenix Contact type 2 surge arrester has no mismatching of plugs, thanks to mechanical coding. It is free of leakage current to ground.Space-saving installation Easy replacement during servicing
Combination of type 2 surge protection and arrester backup fuse, with monitoring of arrester and arrester backup fuse, in combination with a remote indication contact. Design: 3-conductor system (L...
The Phoenix Contact type 1+2 protective device combination has optical and mechanical status indicator. It comes with floating remote indication contact.Plugs can be checked with CHECKMASTER 2 Part...
Attachment connector with surge protection for mains sockets, mains control lamp, optical power and error display. For country-specific use in: D, A, I, NL, S, N, FIN, E, P. Color: White
The Phoenix Contact type 1+2 protective device combination has optical and mechanical status indicator. It comes with floating remote indication contact.Plugs can be checked with CHECKMASTER 2 Part...
Plug-in surge arrester, in accordance with Type 2/Class II, for 3-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE).
The Phoenix Contact combination type 1/2 protective device has optical and mechanical status indicator. It comes with floating remote indication contact.Pluggable High continuous voltage
Pluggable surge protective device free of leakage current, in accordance with Type 2/Class II, for 3-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE), with...
Pluggable surge protective device free of leakage current, in accordance with Type 2/Class II, for 3-phase power supply networks with combined PE and N installed in one conductor (4-conductor syste...
Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for four signal wires with common reference potential. Indirect groundin...