The Siemens SENTRON series 4 pole residual current circuit breaker. It has voltage rating of 400V and operating current of 40A with tripping characteristic class C.Overvoltage category III Operatin...
Circuit Breaker Type = RCCB Current Rating = 40A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 300mA Tripping Characteristics = Type AC Voltage Rating = 400V ac Series = 5SV4644 Better Wor...
Circuit Breaker Type = RCCB Current Rating = 63A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 100mA Tripping Characteristics = Type AC Voltage Rating = 400V ac Series = 5SV4446 Better Wor...
Circuit Breaker Type = RCCB Current Rating = 40A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 100mA Tripping Characteristics = Type AC Voltage Rating = 400V ac Series = 5SV4444 Better Wor...
Circuit Breaker Type = RCCB Current Rating = 80A Number of Poles = 2 Range = SENTRON Trip Sensitivity = 100mA Tripping Characteristics = Type AC Voltage Rating = 230V ac Series = 5SV4417 Better Wor...
Circuit Breaker Type = RCCB Current Rating = 80A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 400V ac Series = 5SV4347 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 63A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 400V ac Series = 5SV4346 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 40A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 400V ac Series = 5SV4344 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 25A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 400V ac Series = 5SV4342 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 80A Number of Poles = 2 Range = SENTRON Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 230V ac Series = 5SV4317 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 63A Number of Poles = 2 Range = SENTRON Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 230V ac Series = 5SV4316 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 40A Number of Poles = 2 Range = SENTRON Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 230V ac Series = 5SV4314 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 25A Number of Poles = 2 Range = SENTRON Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 230V ac Series = 5SV4312 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 16A Number of Poles = 2 Range = SENTRON Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 230V ac Series = 5SV4311 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 63A Number of Poles = 4 Range = SENTRON Tripping Characteristics = Type A Voltage Rating = 400V ac Series = SENTRON 5SV3xxx Better World Product = Yes M...
Circuit Breaker Type = RCCB Current Rating = 80A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 500mA Tripping Characteristics = Type A Voltage Rating = 400V ac Series = SENTRON 5SV3xxx Bet...
Circuit Breaker Type = RCCB Current Rating = 80A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 500mA Tripping Characteristics = Type B Voltage Rating = 400V ac Series = SENTRON 5SV3xxx Bet...
Circuit Breaker Type = RCCB Current Rating = 80A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 500mA Tripping Characteristics = Type B Voltage Rating = 400V ac Series = SENTRON 5SV3xxx Bet...
Circuit Breaker Type = RCCB Current Rating = 63A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 500mA Tripping Characteristics = Type A Voltage Rating = 400V ac Series = SENTRON 5SV3xxx Bet...
Circuit Breaker Type = RCCB Current Rating = 63A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 500mA Tripping Characteristics = Type A Voltage Rating = 400V ac Series = SENTRON 5SV3xxx Bet...
Circuit Breaker Type = RCCB Current Rating = 63A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 500mA Tripping Characteristics = Type B Voltage Rating = 400V ac Series = SENTRON 5SV3xxx Bet...
Circuit Breaker Type = RCCB Current Rating = 63A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 500mA Tripping Characteristics = Type B Voltage Rating = 400V ac Series = SENTRON 5SV3xxx Bet...
Circuit Breaker Type = RCCB Current Rating = 125A Number of Poles = 4 Range = 5SV3 Trip Sensitivity = 500mA Tripping Characteristics = Type A Voltage Rating = 230/400V Series = 5SV3
Circuit Breaker Type = RCCB Current Rating = 125A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 500mA Tripping Characteristics = Type A Voltage Rating = 400V Series = 5SV3745
Circuit Breaker Type = RCCB Current Rating = 40A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 500mA Tripping Characteristics = Type A Voltage Rating = 400V ac Series = SENTRON 5SV3xxx Bet...
Circuit Breaker Type = RCCB Current Rating = 40A Number of Poles = 4 Range = SENTRON Trip Sensitivity = 500mA Tripping Characteristics = Type B Voltage Rating = 400V ac Series = SENTRON 5SV3xxx Bet...
The residual current operated circuit breaker is a 4-pole, Type A unit. In the event of an overload or short-circuit, circuit breakers safely cut off the connected circuit and reliably protect elec...
The residual current operated circuit breaker is a 4-pole, Type B, selective unit. In the event of an overload or short-circuit, circuit breakers safely cut off the connected circuit and reliably p...
Series 5SV3 RCCBs. From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highl...
Series 5SV3 RCCBs. From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highl...
Series 5SV3 RCCBs. From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highl...
The Siemens 5SV3 series residual current operated circuit breaker or RCCB is suitable for personnel and fire protection. The circuit breaker is available in either 2 or 4 pole versions and each bre...
Circuit Breaker Type = Residential MCB Current Rating = 125A Number of Poles = 4 Range = 5SV3 Trip Sensitivity = 300mA Tripping Characteristics = Type A Voltage Rating = 230/400V Series = 5SV3
The residual current operated circuit breaker is a 4-pole, type A unit. In the event of an overload or short-circuit, circuit breakers safely cut off the connected circuit and reliably protect elec...
Series 5SV3 RCCBs. From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highl...
Series 5SV3 RCCBs. From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highl...
The residual current operated circuit breaker is a 4-pole, Type B+, short-time delayed unit. In the event of an overload or short-circuit, circuit breakers safely cut off the connected circuit and ...
The Siemens 5SV3 series residual current operated circuit breaker or RCCB is suitable for personnel and fire protection. The circuit breaker is available in either 2 or 4 pole versions and each bre...
Series 5SV3 RCCBs. From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highl...
Series 5SV3 RCCBs. From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highl...
The residual current operated circuit breaker is a 4-pole, Type B+, short-time delayed unit. In the event of an overload or short-circuit, circuit breakers safely cut off the connected circuit and ...
The Siemens 5SV3 series residual current operated circuit breaker or RCCB is suitable for personnel and fire protection. The circuit breaker is available in either 2 or 4 pole versions and each bre...
Circuit Breaker Type = RCCB Current Rating = 63A Number of Poles = 2 Range = SENTRON Trip Sensitivity = 300mA Tripping Characteristics = Type B Voltage Rating = 230V ac Series = 5SV3626 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 40A Number of Poles = 2 Range = SENTRON Trip Sensitivity = 300mA Tripping Characteristics = Type B Voltage Rating = 230V ac Series = 5SV3624 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 25A Number of Poles = 2 Range = SENTRON Trip Sensitivity = 300mA Tripping Characteristics = Type B Voltage Rating = 230V ac Series = 5SV3622 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 16A Number of Poles = 2 Range = SENTRON Trip Sensitivity = 300mA Tripping Characteristics = Type B Voltage Rating = 230V ac Series = 5SV3621 Better Worl...
Circuit Breaker Type = RCCB Current Rating = 63A Number of Poles = 2 Range = SENTRON Trip Sensitivity = 300mA Tripping Characteristics = Type A Voltage Rating = 230V ac Series = SENTRON 5SV3xxx Bet...
The residual current operated circuit breaker is a 4-pole, type A unit. In the event of an overload or short-circuit, circuit breakers safely cut off the connected circuit and reliably protect elec...
Circuit Breaker Type = RCCB Current Rating = 40A Number of Poles = 2 Range = SENTRON Trip Sensitivity = 300mA Tripping Characteristics = Type A Voltage Rating = 230V ac Series = SENTRON 5SV3xxx Bet...